Options
Katzis, Konstantinos
Loading...
Preferred name
Katzis, Konstantinos
Translated Name
Κάτζης, Κωνσταντίνος
Position
Deputy Dean, Associate Professor
Main Affiliation
School
6 results
Now showing 1 - 6 of 6
- PublicationCreating XML/PHP interface for BAN interoperability(1/1/2017)
;Fragkos, Vasileios; ;Despotou, GeorgeFragkos, VasileiosRecent advances in medical and electronic technologies have introduced the use of Body Area Networks as a part of e-health, for constant and accurate monitoring of patients and the transmission as well as processing of the data to develop a holistic Electronic Health Record. The rising global population, different BAN manufacturers and a variety of medical systems pose the issue of interoperability between BANs and systems as well as the proper way to propagate medical data in an organized and efficient manner. In this paper, we describe BANs and propose the use of certain web technologies to address this issue. - PublicationThe artificial pancreas: Reducing safety risk via intra-peritoneal insulin delivery(1/1/2017)
;Jones, Richard William ;Gianni, Francesco ;Despotou, George; Jones, Richard WilliamThe Artificial Pancreas is a medical device, currently in development, that aims to provide automatic regulation of blood glucose (BG) levels in ambulatory type 1 diabetes mellitus sufferers. The most popular approach utilises subcutaneous (SC) continuous glucose monitoring (CGM) combined with SC insulin injection controlled by a Model Predictive Control (MPC) algorithm. From a safety risk perspective problematic elements include the performance robustness of the CGM and the need for a pre-meal insulin bolus to provide satisfactory post prandial BG regulation. This contribution presents preliminary in silico studies which indicate that the use of an alternative approach to insulin delivery - intra-peritoneal (IP) infusion - could provide a similar level of BG regulation (as obtained with SC delivery), without the need for the pre-meal bolus. This simplified control architecture would remove the patient safety risk related to the administration (or not) of pre-meal bolus. - PublicationImplications and modelling of data quality on confidence of clinical decision support: A conceptual framework(1/1/2017)
;Despotou, George ;Jones, Richard William; ;Bilici, Eda ;Lei, Zhao ;Keung, Sarah Lim Choi ;Arvanitis, T. N.Despotou, GeorgeIntegrated care paradigms depend on multiple sources of data. The quality of data used in decision-making will ultimately affect the delivered care to the patient. Quality includes several dimensions, which may affect the result. This paper presents how data quality dimensions may affect the delivered service, and propose a conceptual framework for the classification of confidence in data used in clinical decision-making for integrated care. - PublicationThe challenges of balancing safety and security in implantable medical devices(1/1/2016)
; ;Jones, Richard William ;Despotou, GeorgeKatzis, KonstantinosModern Implantable Medical Devices (IMDs), implement capabilities that have contributed significantly to patient outcomes, as well as quality of life. The ever increasing connectivity of IMD's does raise security concerns though there are instances where implemented security measures might impact on patient safety. The paper discusses challenges of addressing both of these attributes in parallel. - PublicationUMOD: A Device for Monitoring Postoperative Urination(2018-01-01)
; ;Despotou, George ;Jones, Richard WilliamKatzis, KonstantinosA Urine Monitoring Device (UMOD) has been designed and implemented for monitoring postoperative urination. This device has been created primarily to assist nurses and doctors monitor patients during their postoperative and recovery period. Furthermore, to reduce the burden of the nursing staff required to regularly monitor and empty the urine bags saving them precious time. The device consists of a stand and a load cell where the urine bag is attached. The stand is light and can easily move shall the patient require to move. An ESP Wi-Fi microprocessor module is used to calculate the rate of flow of urine in real time, identify and ignore any false readings due to accidental movements of the urine bag using an accelerometer and transmit the readings to a server / cloud through the local Wi-Fi. - PublicationTotally connected healthcare with TV white spaces(1/1/2017)
;Jones, Richard William ;Despotou, George; Katzis, KonstantinosRecent technological advances in electronics, wireless communications and low cost medical sensors generated a plethora of Wearable Medical Devices (WMDs), which are capable of generating considerably large amounts of new, unstructured real-time data. This contribution outlines how this data can be propagated to a healthcare system through the internet, using long distance Radio Access Networks (RANs) and proposes a novel communication system architecture employing White Space Devices (WSD) to provide seamless connectivity to its users. Initial findings indicate that the proposed communication system can facilitate broadband services over a large geographical area taking advantage of the freely available TV White Spaces (TVWS).