Options
Robotic resection of duodenal adenoma
Author(s)
Marzano, Ettore
Addeo, Pietro F.
Oussoultzoglou, Elíe
Jaeck, Daniel
Pessaux, Patrick
Abstract
Background: Duodenal sporadic adenomatous polyps are rare findings during upper endoscopy. Resection is indicated due to their malignant potential. +Methods: A 55 year-old male patient was diagnosed with a 3 cm duodenal adenomatous polyp with low-grade dysplasia, which could not be safely resected by endoscopy. A transduodenal submucosal robotic-assisted polypectomy was performed. +Results: The operative time was 4.5 h, with an estimated blood loss of 200 ml. The patient had a normal bowel transit on postoperative day 3 and he was discharged on postoperative day 7. Three months follow-up was uneventful. The final histological finding revealed a completely resected duodenal adenomatous polyp without signs of malignancy. +Conclusion: Robotic-assisted resection of duodenal polyps is a feasible technique that may be indicated for the local excision of duodenal lesions that cannot be endoscopically resected. Compared to the open and laparoscopic approach, it offers many technical advantages.
Part Of
International Journal of Medical Robotics and Computer Assisted Surgery
Issue
1
Volume
7
Date Issued
2011-03-01
Open Access
No
DOI
10.1002/rcs.371
Department